How to connect to the License server
Within the same network
When the licensing server is in the same subnet as the client, and all communication via TCP and UDP port 1947 is possible, no further communication settings are required.
All other cases require additional settings:
- In your browser open the Sentinel Admin Control Center via http://localhost:1947
- Go to Configuration – Access to remote license managers
- Configure these settings:
- Press “Submit” after making changes, and wait a few minutes. The changes are now applied
Outside the network
Working from home
You have a stable internet connection at your remote location
This can be done in two ways:
- VPN connection: This is the most secure, because a username and password can be set to have set up the VPN-connection
- Fixed external IP address: which can then be set up port forwarding on the router for traffic over port 1947 to the license server. This is the least secure, because this cannot be password-protected via the Sentinel License Manager
Working outdoors
No (stable) internet connection at the remote location then you can 'borrow' a license by detaching a license from the License server
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article